IR150

Reimagined for the mission critical liquid cooling era, the NeuCool® IR150 offers a plug-and-play solution for high-density, two-phase-enabled deployments. The design vertically integrates a two-phase CDU directly into a 200mm portion of an 800mm-wide IT enclosure, providing 150kW of liquid cooling capacity.

1

2

3

4

5

MR250

The NeuCool™ MR250 is a highly engineered two-phase, direct-to-chip cooling solution designed to provide up to 250kW of liquid cooling capacity to support large-scale deployments of high-density racks.

Product Features

3 15” NeuView™ Touchscreen

  • System monitoring and controls with NeuView touchscreen and DCIM integration
  • Intuitive mimic display visually supports servicing

4 Vaporators & Manifolds

  • Integrated row manifolds from CDU to rack(s) and in-rack manifolds
  • Integrated in-server plumbing and vaporators with compatible servers

5 Pumps & Controls

  • Efficiently circulates the refrigerant throughout the IT loop between the servers
  • 2 pumps (1+1 redundant) and automatic pump switchover in case of failure ensures maximum uptime
  • Redundant core logic and sensors control system

IR150

Reimagined for the mission critical liquid cooling era, the NeuCool® IR150 offers a plug-and-play solution for high-density, two-phase-enabled deployments. The design vertically integrates a two-phase CDU directly into a 200mm portion of an 800mm-wide IT enclosure, providing 150kW of liquid cooling capacity.

Product Features

1 Brazed Plate Heat Exchanger

  • Condenses refrigerant vapor and transfers heat from the IT loop to the facility water loop
  • Facility water connection at top-rear

2 7" NeuView™ Touchscreen

  • System monitoring and controls with NeuView touchscreen and DCIM integration
  •  Intuitive mimic display visually supports servicing

3 NeuCool Reservoir

  •  Storage tank provides:
    • Inlet pressure for pumps
    • Expansion volume to accommodate full transients from zero to full power without interruptions

4 Vaporators & Manifolds

  • Integrated liquid and vapor rack manifolds
  • Supports plug-and-play deployment of servers enabled with two-phase vaporators and robust in-server plumbing

5 Pumps & Controls

  • Efficiently circulates the refrigerant throughout the IT loop between the servers
  • 2 pumps (1+1 redundant) and automatic pump switchover in case of failure ensures maximum uptime
  • Redundant core logic and sensors control system

Learn More

Key Benefits:

Pre-Integrated Solution

  • CDU (150kW)
  • 42U IT rack space
  • Liquid and vapor manifolds

Modular & Scalable

  • Single-rack failure domain
  • Simplifies deployment of two-phase-enabled servers

Racks Redesigned For The Liquid Cooling Era

  • Unique vertical integration of CDU enables complete separation of mechanical and IT components
  • Optimized for the modern era of overhead facility water
Contact Us
<div class="center-wr">

  <div class="produc-spec-wr-left">
    <div class="produc-spec-wr">
      <table>
        <thead>
          <tr>
            <th>Feature</th>
            <th>Specification</th>
          </tr>
        </thead>
        <tbody>
          <tr>
            <td>Liquid Cooling Capacity (kW)</td>
            <td>250kW</td>
          </tr>
          <tr>
            <td>Racks Supported</td>
            <td>1 or 2</td>
          </tr>
          <tr>
            <td>Height</td>
            <td>98 in. (2489 mm)</td>
          </tr>
          <tr>
            <td>Width</td>
            <td>31.5 in. (800mm)</td>
          </tr>
          <tr>
            <td>Depth</td>
            <td>47 in. (1200 mm)</td>
          </tr>
          <tr>
            <td>Display</td>
            <td>15" LCD touchscreen</td>
          </tr>
          <tr>
            <td>Input Voltage</td>
            <td>230VAC/400VAC/480VAC 50/60Hz, N+1 redundant</td>
          </tr>
          <tr>
            <td>Max System Power Consumption</td>
            <td>2.6kW</td>
          </tr>
          <tr>
            <td>Targeted Server Heat Removal</td>
            <td>CPUs and GPUs, ~75-80%</td>
          </tr>
          <tr>
            <td>Max Operating Pressure</td>
            <td>55 psi</td>
          </tr>
          <tr>
            <td>Pumps</td>
            <td>2</td>
          </tr>
          <tr>
            <td>Refrigerant</td>
            <td>R-1233zd(E): Shown specs R-515B: Specs in mid-2025, higher performance</td>
          </tr>
          <tr>
            <td>Facility Water Flow Control</td>
            <td>Characterized Control Valve (CCV)</td>
          </tr>
        </tbody>
      </table>
    </div>
  </div>

  <div class="produc-spec-wr-right">
    <div class="produc-spec-wr">
      <table>
        <thead>
          <tr>
            <th>Feature</th>
            <th>Specification</th>
          </tr>
        </thead>
        <tbody>
          <tr>
            <td>Water Leak Detection</td>
            <td>Sense cable</td>
          </tr>
          <tr>
            <td>ASHRAE Compatibility (at rated performance)</td>
            <td>W27</td>
          </tr>
          <tr>
            <td>ASHRAE Compatibility (derated perf.)</td>
            <td>W45</td>
          </tr>
          <tr>
            <td>Redundancies</td>
            <td>Pumps (1+1), dual main power feeds, sensors</td>
          </tr>
          <tr>
            <td>Hot Swappable</td>
            <td>Pumps, power supply units, sensors, main control board, LCD</td>
          </tr>
          <tr>
            <td>Warm Rack Expansion</td>
            <td>One rack → Two racks</td>
          </tr>
          <tr>
            <td>Flow Rate (Facility)</td>
            <td>375 Liters/min</td>
          </tr>
          <tr>
            <td>Unit Weight (Charged)</td>
            <td>CDU & Overhead Manifold: ~1400 lbs</td>
          </tr>
          <tr>
            <td>Communication Protocols</td>
            <td>Redfish, SNMP, Modbus, IPMI, etc.</td>
          </tr>
          <tr>
            <td>Filter and Pressure Relief Valve</td>
            <td>20 μm filter, integrated pressure relief valve</td>
          </tr>
        </tbody>
      </table>
    </div>
  </div>

</div>
.center-wr {
  max-width: 1200px;
  margin: 0 auto;
  padding: 0;
}

.produc-spec-wr-left {
  display: inline-block;
  vertical-align: top;
  width: 49%;
}

.produc-spec-wr-right {
  display: inline-block;
  vertical-align: top;
  width: 49%;
}

.produc-spec-wr {
  margin: 10px 0 0 0;
}

.produc-spec-wr tr th {
  background: #1d215f;
  color: #fff;
  font-size: 18px;
  line-height: 25px;
  padding: 10px;
  width: 100%;
  text-align: left;
  font-family: "Montserrat";
}

.produc-spec-wr tr {
  background: #fff;
}

.produc-spec-wr tr:nth-child(odd) {
  background: #00AEEF;
}

.produc-spec-wr tr td {
  color: #000;
  font-size: 14px;
  line-height: 25px;
  padding: 10px;
  font-family: "Montserrat";
}

.col-1 {
  width: 38%;
}

.col-2 {
  width: 60%;
}

@media only screen and (max-width: 979px) {
  .produc-spec-wr-left,
  .produc-spec-wr-right {
    display: block;
    width: 100%;
  }
}
Contact Us

CPUs:

  • Intel Sapphire Rapids
  • Intel Emerald Rapids
  • AMD EPYC Genoa
  • AMD EPYC Turin
  • NVIDIA Grace

GPUs:

  • NVIDIA H100
  • NVIDIA H200
  • AMD MI325X
  • AMD MI355X
  • NVIDIA B200